Plants open · Mallavarappadu & GundlapalliMon – Sat · 9:30 AM – 6:00 PM
Global Readymix& Global Metals
తెలుగు
HomeConcreteAggregatesPlantsOn-siteAboutContact

M30 ready-mix
concrete

M30 is the IS 456 minimum for severe exposure and the default grade for high-rise structural elements, bridge decks, industrial floors, and any water-retaining RCC.

30N/mm²
28-day compressive strength
100 – 150 mm
Workability (slump)
Severe
IS 456 exposure class
Technical specifications

M30 mix design parameters

IS 456:2000 durability minimums for the severe exposure class. Project-specific mix designs are signed off by our QC team.

Characteristic compressive strength
30 N/mm² @ 28 days
Workability (slump range)
100 – 150 mm
Nominal maximum aggregate size
20 mm
IS 456 exposure class
Severe
Minimum cement content
320 kg/m³ minimum
Maximum free water / cement ratio
0.45
Most popular use
High-rise structural, bridges, industrial floors, water-retaining.
Use cases

Where M30 fits — and where it doesn't

Specifying the right grade saves money and avoids rework. Below is a quick guide based on IS 456 norms and our delivery experience in Prakasam district.

Use M30 for

  • High-rise residential structural columns and beams (G+5 and above)
  • Bridge decks and overpass slabs
  • Water-retaining tanks, reservoirs, treatment plants
  • Industrial flooring under heavy fork-lift or machinery load
  • Pre-stressed concrete beams and slabs
  • Deep foundations in coastal areas
  • Sewerage and drainage structures

Don't use M30 for

  • Marine immersion / chloride-rich environments (use M40+)
  • Where M25 meets spec (uneconomical step-up)
Engineering notes

How we batch M30

IS 456 Table 5 sets M30 as the durability minimum for severe exposure: 320 kg/m³ cement, 0.45 max w/c. Mixes typically incorporate fly-ash (15 – 25% replacement) or GGBS for long-term durability and reduced heat of hydration. Pumpable to ~30 m height with standard equipment; higher with boom pumps.

Every dispatch from our Mallavarappadu and Gundlapalli plants includes a batch slip with mix proportions and a 28-day cube test report — generated from the same load you receive. M30 is delivered in transit mixers and placed either by direct chute discharge or by line pump for upper-floor slabs, columns, and pours the truck can't reach. For projects above 50,000 m³, we can set up a dedicated batching plant on your site with a project-specific mix design and on-site QC lab.

FAQ

Common questions about M30

Do I need M30 for my G+5 apartment building?
Likely yes for the structural columns and beams; slabs may still be M25 depending on the structural design. Always follow your structural engineer's specification — the grade can vary element-by-element in the same building.
Why is fly-ash used in M30 mixes?
Fly-ash reduces heat of hydration (lower thermal cracking in thick pours), improves long-term durability, and reduces permeability — all helpful for severe-exposure and water-retaining structures.
Service area

M30 delivery across Ongole and Prakasam district

We dispatch M30 ready-mix concrete to construction sites in Ongole and the wider Prakasam district from our Mallavarappadu and Gundlapalli plants. Tap any town for plant distance, transit time, and project-specific notes.

Order M30 today
Same-day dispatch on confirmed orders